Model XDLC communicates detector data, such as the sensitivity of intelligent fire detectors and logic function information, to the Cerberus PRO Modular Operating Unit (Model FCM2041- U3), which is located within a given Cerberus PRO Modular system.Įach device loop card supports four (4) `Class A’, eight (8) `Class B’ circuits for up to a total of 252 addressable devices – as well as relay and audible bases, remote lamps and duct-detector housings in any combination. Planning Tool Cerberus PRO UL - Flyers A6V10384669en. Model XDLC is polarity insensitive via SureWire technology, which greatly reduces commissioning time normally spent tracing down crossed-field wiring.
#Siemens cerberus pro programming software#
Backed by Siemens support, programs and initiatives. The programming software for the 252 / 504-point fire systems is held in flash electrically erasable programmable read-only memory (EEPROM).
#Siemens cerberus pro programming full#
A full line of addressable detectors and devices offered from the Siemens portfolio. The Cerberus PRO Modular system is ideal for large market applications such as data centers, high rise buildings, hospitals & universities. Easy to install, affordable and has the latest innovations offered by Siemens. The system is a very powerful market-leading. At Senseco, we have installed many Cerberus pro systems in a variety of different buildings. Model XDLC communicates all relevant device and event data (`Alarm’, `Trouble’ and `Supervisory’ commands) to a Cerberus PRO Modular fire-alarm control panel (FACP), and supervises the device loop circuit. Cerberus PRO Compact offers: Fire (FC922/924) & Fire with Voice (FV922/924) system options. The Cerberus Pro system is the Open Protocol fire detection system available from Siemens Cerberus Pro approved agents of which there are hundreds across the world and over 20 in the UK. The `Class X’ Device Loop Card (Model XDLC) initializes, operates, and maintains all devices residing on up to four (4) `Class A’, eight (8) `Class B’ addressable circuits. Model XDLC has 16 LEDs for diagnostic purposes and provides ground-fault detection and zone isolation circuitry. Model XDLC takes one (1) address on the network, communicating up to a total of 252 detectors and devices. Programming for Model XDLC is accomplished via the Cerberus PRO Modular system custom-configuration tool, Zeus-C. The Siemens – Fire Safety `Class X’ Device Loop Card (Model XDLC Siemens) is the interface used for connecting Siemens addressable, intelligent `X’ as well as `H’-series devices.Įach Model XDLC plugs into one (1) slot of the Model CC-2 or Model CC-5 card cage.
![siemens cerberus pro programming siemens cerberus pro programming](https://img.yumpu.com/23324334/1/500x640/cerberus-pro-aeur-enjoy-protecting-siemens.jpg)
![siemens cerberus pro programming siemens cerberus pro programming](https://demo.vdocument.in/img/378x509/reader022/reader/2020081609/5f1c4ceff6d8c9093464e728/r-2.jpg)
Description XDLC Siemens Device Loop Card Interface Unit for the Cerberus PRO FACP.